Skip to main content
Drag

Redkleen RX 400 Radiator Flush Cleaner

Its wide range of usage is in water treatment, because it can act as an coagulant, flocculant, precipitant and emulsion breaker. As coagulant and flocculant, aluminum sulfate successfully removes turbidity, suspended solids and colloidal color,reduces biochemical oxygen demand (BOD) and extremely clarifies potable, process and wastewaters.

Redkleen RX 400 Radiator Flush Cleaner
Radiator and AC coil cleaner-39

Redkleen RX 400 Radiator Flush Cleaner

Part No: RXSOL-40-4051-025

it can act as an coagulant, flocculant, precipitant and emulsion breaker. As coagulant and flocculant, aluminum sulfate successfully removes turbidity, suspended solids and colloidal color,reduces biochemical oxygen demand (BOD) and extremely clarifi

Its wide range of usage is in water treatment, because it can act as an coagulant, flocculant, precipitant and emulsion breaker. As coagulant and flocculant, aluminum sulfate successfully removes turbidity, suspended solids and colloidal color,reduces biochemical oxygen demand (BOD) and extremely clarifies potable, process and wastewaters.

Application

Also used as foam fire extinguisher 

Aluminium sulfate reacts with sodium bicarbonate to which foam stabilizer has been added, producing carbon dioxide for fire extinguishing foam. 

 

 

 

  • Al2(SO4)3 + 6 NaHCO3 → 3 Na2SO4 + 2 Al(OH)3 + 6 CO2

    The carbon dioxide is trapped by the foam stabilizer and creates a thick foam which will float on top of hydrocarbon fuels and seal off access to atmospheric oxygen, smothering the fire. Chemical foam was unsuitable for use on polar solvents such as alcohol, as the fuel would mix with and break down the foam blanket. The carbon dioxide generated also served to propel the foam out of the container, be it a portable fire extinguisher or fixed installation using hoselines. Chemical foam is considered obsolete in the United States and has been replaced by synthetic mechanical foams, such as AFFF which have a longer shelf life, are more effective, and more versatile, although some countries such as Japan and India continue to use it.

  •  

     

     

    In the construction industry, it is used as waterproofing agent and accelerator in concrete.

    Dosage

    - For the production of Aluminum salts, Soaps and Aluminum Hydroxide Gel. - As a Catalyst in Ethane Production.
    - Textile industry.
    - Paper production. 

    - For the production of Glycerin
    - As a Foaming Agent in Fiber Foams.
    - As a Clearing Agent for Fats and Foams. - In sugar industry. 

    Technical Specification

     

    Item

    Index

    Aluminum Sulfate

    15.8%

    17%

    A12O3 % ≥

    15.8

    17

    Iron Fe content % ≤

    0.50

    0.005

    Water insoluble matter % ≤

    0.15

    0.15

    PH value 1% aqueous solution ≥

    3.0

    3.0

    Heavy metals as Pb % ≤

    0.002

    0.002

    AS % ≤

    0.0005

    0.0005

    Granularity ≥

    -----

    15

     

    Item

    Index

    Aluminum Sulfate

    15.8%

    17%

    A12O3 % ≥

    15.8

    17

    Iron Fe content % ≤

    0.50

    0.005

    Water insoluble matter % ≤

    0.15

    0.15

    PH value 1% aqueous solution ≥

    3.0

    3.0

    Heavy metals as Pb % ≤

    0.002

    0.002

    AS % ≤

    0.0005

    0.0005

    Granularity ≥

    -----

    15

     

    Item

    Index

    Aluminum Sulfate

    15.8%

    17%

    A12O3 % ≥

    15.8

    17

    Iron Fe content % ≤

    0.50

    0.005

    Water insoluble matter % ≤

    0.15

    0.15

    PH value 1% aqueous solution ≥

    3.0

    3.0

    Heavy metals as Pb % ≤

    0.002

    0.002

    AS % ≤

    0.0005

    0.0005

    Granularity ≥

    -----

    15

     

    MSDS

    Porduct Name               ALUMINIUM SULPHATE
    Part Number   RXSOL-40-1904-025

    RX MARINE INTERNATIONAL
    105, A wing , BSEL , TECH PARK.
    VASHI ,NEW BOMBAY 400703 INDIA

    Branch : Kandla, Mumbai , Chennai, Vizag, Kolkata, UAE , OMAN , CANADA and KENYA  

    Phone +91 22 20871200 - 1400
    Fax +91 22 27612100 :::AOH :0091 9821214367
    Email mail@rxmarine.com
    Website www.rxmraine.com

    Chemical Name                 Cas No                        EC No              Weight                          Formula                   
    Aluminum sulfate 10043-01-3 233-135-0 342,15 g/mol Al2O12S3
    Signal Word  Danger
    Hazard Statements H290 May be corrosive to metals. H318 Causes serious eye damage.
    Precautionary statements   P234 Keep only in original packaging. P280 Wear eye protection/ face protection. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P390 Absorb spillage to prevent material damage.
    Classification of the substance or mixture No data available
    Supplemental Hazard      Statements No data available
    Other hazards  This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher

    General advice Show this material safety data sheet to the doctor in attendance
    If inhaled After inhalation: fresh air.
    Eye Contact  After eye contact: rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.
    Swallowed After swallowing: fresh air. Make victim drink 
    Skin Contact   In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower. Call a physician immediately.
    Inhalation No data available
    Ingestion No data available
    Most important symptoms and effects, both acute and delaye The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11
    Indication of any immediate medical attention and special treatment needed  No data available

    Flammability                                                  No data available
    Suitable extinguishing media  Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
    Unsuitable extinguishing media For this substance/mixture no limitations of extinguishing agents are given. 
    Special hazards arising from the substance or mixture  Sulfur oxides Aluminum oxide Not combustible. Ambient fire may liberate hazardous vapours.
    Further information Suppress (knock down) gases/vapors/mists with a water spray jet. Prevent fire extinguishing water from contaminating surface water or the ground water system.
    Hazardous combustion
    products
    Fire may cause the evolution of Sulphur oxides, nitrogen oxides.
    Advice for firefighters In the event of fire, wear self-contained breathing apparatus. 
    Protective Equipment No data available
    Specific Hazards Arising from the Chemical No data available

    Personal precautions, protective equipment and emergency procedures Advice for non-emergency personnel: Do not breathe vapors, aerosols. Avoid substance contact. Ensure adequate ventilation. Keep away from heat and sources of ignition. Evacuate the danger area, observe emergency procedures, consult an expert. For personal protection see section 8
    Spillage

    No data available

    Personal Protection No data available
    Enviromental Precaution Do not let product enter drains. Risk of explosion. 
    Methods and materials for
    containment and cleaning
    Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up carefully with liquid-absorbent material (e.g. Chemizorb®). Dispose of properly. Clean up affected area. 
    Reference to other sections    For disposal see section 13.

    Advice on protection against fire and explosion No data available
    Incompatible materials  No data available
    Hygiene measures No data available
    Advice on safe handling  No data available
    Conditions for safe storage, including any incompatibilities  Tightly closed. Dry. Keep in a well-ventilated place. Keep locked up or in an area accessible only to qualified or authorized persons. Moisture sensitive.
    Storage conditions No metal containers. Tightly closed. Dry. hygroscopic Store under inert gas
    Storage class Storage class (TRGS 510) 8B Non-combustible, corrosive hazardous materials
    Specific end use(s) Apart from the uses mentioned in section 1.2 no other specific uses are stipulated 
    Advice on general occupational hygiene No data available

    Exposure controls 

    Personal Protective equipment.

    Engineering Control No data available
    Eye/face protection Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
    Body Protection Protective Clothing.
    Skin protection No data available
    Respiratory protection
    Required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P2 The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
    Other Protection  Measure No data available
    Control of    environmental exposure Do not let product enter drains. Risk of explosion. 

    Physical state Powder
    Colour White 
    Odour Odorless 
    Odor Threshold No data available 
    pH No data available
    Melting Point 770 °C - dec. 
    Boiling Point 112 - 116 °C
    Flash Point No data available 
    Evaporation Rate Not data available 
    Flammability (solid, gas) No data available
    Explosive limits No data Available
    Upper/lower flammability or explosive limits No data available 
    Autoignition temperature No data available 
    Decomposition temperature  No data available
    Vapour pressure No data available                                                   
    Viscosity No data available 
    Density 2,71 g/mL at 25 °C - lit. 
    Relative Density No data available 
    Specific Gravity No data available 
    Partition coefficient No data available
    Explosive properties No data available 
    Solubility ca.0,00001 g/l at 21,5 °C - insoluble
    Ignition temperature No information available.
    Particle characteristics No data available 

    Reactivity                        No data available
    Chemical stability The product is chemically stable under standard ambient conditions (room temperature) . 
    Possibility of hazardous reactions No data available
    Conditions to avoid Air Exposure to moisture                                                                          
    Incompatible materials
    No data available
    Hazardous decomposition products In the event of fire: see section 5

    Acute toxicity  LD50 Oral - Rat - male and female - > 2.000 mg/kg (OECD Test Guideline 401) Inhalation: No data available LD50 Dermal - Rabbit - male and female - > 5.000 mg/kg (OECD Test Guideline 402)                 
    Skin corrosion/irritation Skin - Rabbit Result No skin irritation - 4 h (OECD Test Guideline 404)
    Serious eye      damage/irritation Eyes - Rabbit Result: Irreversible effects on the eye (OECD Test Guideline 405)
    Respiratory or skin    sensitization  Local lymph node assay (LLNA) - Mouse Result: negative (OECD Test Guideline 429)
    Carcinogenicity No data avialable
    Germ cell        mutagenicity  Test Type Ames test Test system Escherichia coli/Salmonella typhimurium Metabolic activation with and without metabolic activation Method: OECD Test Guideline 471 Result: negative Test Type: In vitro mammalian cell gene mutation test Test system mouse lymphoma cells Metabolic activation with and without metabolic activation Method OECD Test Guideline 476 Result:negative Test Type: Micronucleus test Test system Human lymphocytes Metabolic activation with and without metabolic activation Method OECD Test Guideline 487 Result: negative Test Type: Micronucleus test Species Rat Application Route Oral Method OECD Test Guideline 474 Result negative  (in analogy to similar products) The value is given in analogy to the following substances: aluminium hydroxide Species: Rat Application Route: Oral Cytogenetic analysis
    Reproductive toxicity  No data availalble
    Specific target organ toxicity - single      exposure
    Mixture may cause respiratory irritation.
    Additional Information The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher. Repeated dose toxicity - Rat - male - Oral - NOAEL (No observed adverse effect level) - 18 mg/kg - LOAEL (Lowest observed adverse effect level) - 90 mg/kg Remarks: (in analogy to similar products) The value is given in analogy to the following substances: aluminium(III) chloride, anhydrous RTECS: BD1700000 To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated. To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated. 

    Persistence and degradability The methods for determining biodegradability are not applicable to inorganic substances
    Toxicity to fish  Semi-static test LC50 - Danio rerio (zebra fish) - > 87,5 mg/l - 96 h (OECD Test Guideline 203)
    Toxicity to daphnia and other aquatic invertebrates Static test EC50 - Daphnia magna (Water flea) - > 200 mg/l - 48 h (OECD Test Guideline 202)
    Toxicity No data available
    Toxicity to bacteria  Static test EC50 - activated sludge - > 200 mg/l - 3 h (OECD Test Guideline 209)
    Toxicity to algae Static test ErC50 - Pseudokirchneriella subcapitata (microalgae) - 0,24 mg/l - 72 h (OECD Test Guideline 201) 
    Products Biodegradation No data available
    Mobility in soil No data available
    Results of PBT and vPvB assessment This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
    Endocrine disrupting      properties The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher
    Other adverse effects No data available .

    Product See www.retrologistik.com for processes regarding the return of chemicals and containers, or contact us there if you have further questions.

    UN number ADR/RID:3260              IMDG:3260                 IATA:3260 
    UN proper shipping name  ADR/RID:CORROSIVE SOLID, ACIDIC, INORGANIC, N.O.S. (aluminium sulfate)    IMDG:CORROSIVE SOLID, ACIDIC, INORGANIC, N.O.S. (aluminium sulfate)      IATA:CORROSIVE SOLID, ACIDIC, INORGANIC, N.O.S. (aluminium sulfate)
    Transport hazard class(es)      ADR/RID: 8                     IMDG:8                         IATA:8
    Packaging group ADR/RID: Ill                    IMDG: llI                        IATA:Ill
    Environmental hazards ADR/RID:No                   IMDG:No                     IATA: No
    Special precautions for user Tunnel restriction code (E)
    Further information No data available

    Safety, health and environmental regulations/legislation specific for the substance or mixture This material safety data sheet complies with the requirements of Regulation (EC) No. 1907/2006.
    Other regulations Take note of Dir 94/33/EC on the protection of young people at work.
    Chemical Safety Assessment A Chemical Safety Assessment was not carried out for this substance. 

    Other Information

    The information above is believed to be accurate and represents the  best information   currently    available  to us.  However,   we   make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and  weassume  no liability resulting from its use. Users should make  their  own  investigations  to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Rx Marine International  has been advised of the possibility of such damages.

    DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.