The copper sulfate test is used to detect the presence of metallic iron and iron oxide on the surface of materials.
Question - What solution strength is needed to copper sulfate solution can be used to determine if a metal is stainless steel or just steel ?
Answer - Copper sulfate (CuSO4*5H2O) + H2SO4 (anywhere from 1% to 50% is specified in various test methods).