Scale Remover 1507

Size:

Color:

Product Short Description: Scale dissolver. Specifically formulated to remove rust and water scale build up from boiler evaporators, heat exchangers, cooling systems, pipeline collection system etc. Highly effective on heating. Safe and easy handling and storage.
Product Technical Specification:

PRODUCT PROPERTIES of Safe Acid Descalex powder

HS CODE of Safe Acid Descalex powder 34021300

Appearance Reddish / Yellowish / white – Powder ( without indicator )  
Density 1.2g/cm3  
pH (10 wt %):1.1  
Compatibility  
Metal    Avoid aluminium, zinc, tin and their alloys. Avoid galvanised surfaces  
Rubber No known effect  
Packaging Order No.: RXSOL-54-1008-025 Size (in kg)25 , 5
Remarks:

-   Prevent run off water from entering drains if possible

Formation of Calcium Sulfate is main cause for SCALE formation :::

The principal problem potential posed by sulfate ions in water is the possibility of calcium sulfate scale formation.  Precipitation of calcium sulfate can occur when high concentrations of both calcium and sulfate exist simultaneously.  There are three primary areas of water treatment in which calcium sulfate precipitation may occur boilers, cooling systems, and ion exchangers operating in the hydrogen or acid mode.

In boilers, calcium sulfate scale formation has been reduced to a minimum by modern treatment practices.  The low hardness levels largely preclude calcium sulfate boiler scale.    By contrast, cooling systems are subject to calcium sulfate scale deposition because the makeup is usually not treated for hardness removal.  Cooling water is usually treated with sulfuric acid for pH control, and the makeup is cycled, i.e. concentrated.  Calcium sulfate scale deposition can  result unless the cycles of concentration are properly controlled in conjunction with the proper use of scale control chemicals.  Cation ion exchangers regenerated with sulfuric acid also can pose a major calcium sulfate problem. Calcium sulfate precipitation can be avoided by controlling the acid concentration and the flow rate through the exchanger.  

Sulfate content can be calculated in Laboratory by using this method ::: http://rxmarine.com/SULFATE-TEST-KIT

Images: Alt



Sodium Hydroxide 48

Size:

Color:

Product Short Description: Sodium Hydroxide Liquid General Use: Drinking water treatment, papermaking and other manufacturing applications, Detergent and soap industries etc.
Product Technical Specification:

Chemical Name

Percent

Value

Test Method

Sodium hydroxide(NaOH),min.

%

48-55

STAS3068

Sodium carbonate (Na2CO3), max

%

0.7

STAS3068

Water

%

45-52 

 

Appearance: Liquid, clear to slight haze, colorless to light grey tint. 
Odor: No odor  
pH: 14 as is basis 
Melting/Freeze point-range: -18⁰C - -12.8⁰C (0⁰F-5⁰F) approx. 
Boiling point-range: 110⁰C-113⁰C (230⁰F- 236⁰F) approx. 
Flash point: NA 
Evaporation rate: NA  
Flammability: Not flammable. 
Upper/lower flammability limits: NA 
Vapor pressure: NA 
Vapor density: NA Relative 
Water Solubility: Complete. 
Partial coefficient: n-octanol/water: NA 
Auto ignition: NA 
Decomposition temperature: NA 
Viscosity: 7-10 cps @ 20⁰C (68⁰F)

Remarks:
Images: Alt



Aqua Soft Water Softener

Size:

Color:

Product Short Description: Water Softener regeneration product for ion exchange softeners that removes hardness forming calcium and magnesium. It prevents scale, improves heat transfer and protects boilers and pipelines.
Product Technical Specification:
Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



FRESH WATER GENERATOR TREATMENT

Size:

Color:

Product Short Description: Neutral Liquid for prevention of scale in seawater Evaporators
Product Technical Specification:
CharactersItics   Properties
Appearance Thermal Firmness Clear  yellow liquid 250° C            By keeping heat transfer surfaces free of scale, Ensures that the evaporator works at maximum efficiency.
Density In g/cm3 at 15°C: 1.1

Permits more efficient evaporation.

pH (1 Vol%) 9

Reduces downtime and maintenance costs.

Compatibility   Concentrated, safe liquid, easy and economical dosing.
Metal No known effect

For use in both high pressure and vacuum evaporators

Rubber No known effect The antifoaming properties ensure that distillate quality is high
Packaging

20 / 25 ltr

Improves the quality of distilled water

Remarks:

RXSOL-51-6001-025 is a concentrated  solution of a POLYELECTROLYTE  polymer and Antifoaming Agents for  use in SEA WATER evaporator  as a controller of scale and foam in side the  evaporators.  It can be used as a scale inhibitor  in the  feed water  to EVAPORATORS producing fresh water .

A liquid polymer-based evaporator treatment specially designed to control and prevent scale formation in evaporators

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



AQUATEX 6460

Size:

Color:

Product Short Description: Corrosion and Scale Inhibitor with Phosphates and Polyphosphates.
Product Technical Specification:
Property Value
Appearance Clear to slightly hazy amber liquid
Odor Mild characteristic
pH (as supplied) Alkaline
Specific Gravity @ 25°C 1.10 – 1.20
Solubility Fully water soluble
Freeze Point Below 0°C
Shelf Life 12 months (sealed container)

 

Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



CHEMZOL 941

Size:

Color:

Product Short Description: Corrosion and Scale Inhibitor with Phosphates and Polyphosphates.
Product Technical Specification:
Parameter Result
Appearance Paly Yellow, Clear liquid
Density 1.01-1.1
Boiling Poitnt  100 degree celcius
Remarks:

Frequently Asked Questions about Boiler treatment

Q1. What is a corrosion scale inhibitor and why is it important for boilers?

Answer:

A corrosion scale inhibitor is a chemical solution designed to prevent rust, corrosion, and scale formation inside boiler systems. It protects metal surfaces from degradation and ensures smooth heat transfer, ultimately extending the lifespan of the boiler and reducing energy costs and maintenance downtime.

Q2 How do I choose the right scale inhibitor for my boiler?

Answer:

Choosing the right inhibitor depends on:

  • Boiler pressure and temperature

  • Feedwater quality (e.g., hardness, pH, oxygen content)

  • Type of scaling or corrosion (e.g., calcium carbonate vs. oxygen pitting)

Look for inhibitors that are multi-functional, offering both scale and corrosion protection, and ensure they’re compatible with your boiler material (carbon steel, copper alloys, etc.).

Q3 How often should I dose my boiler with a corrosion scale inhibitor?

Answer:

The frequency of dosing depends on your boiler’s operating conditions, feedwater quality, and the type of inhibitor used. Typically, dosing is done continuously through a dosing pump or daily during boiler operation. Regular water testing and monitoring (pH, conductivity, hardness) is essential to maintain the correct inhibitor levels and ensure optimal protection against corrosion and scale.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



CHEMZOL 9200

Size:

Color:

Product Short Description: Extremely suitable oxygen scavenger for low and medium pressure boilers.
Product Technical Specification:

 

Solubility (10 % Aquous Soln)  V. S. Hazy to clear solution.
pH Value of 5% Solution 3.5 to 4.5
Specific Gravity @ 25° C  1.310 – 1.370
Density, lbs/gal @ 25° C 10.9 - 11.3
Description Oxygen Scavenger for Boiler
Standard Packing 30 Kg / 50 Kg. / 250 kg HM HDPE Barrel
Remarks:

The most common oxygen scavengers in oilfield production are sodium bisulfite (SBS) and ammonium bisulfite (ABS). Ammonium bisulfite is more water soluble than sodium bisulfite and typically react with oxygen faster. However, ammonium in the ammonium bisulfite can promote bacteria growth.

Being a salt of a weak acid and a strong base, sodium bisulfite forms a significantly basic aqueous solution whereas ammonium bisulfite is only slightly basic at around pH 8. As a rule of thumb, 60ppm of 65wt% ammonium bisulfite is required to reduce the oxygen concentration in water from 9ppm to 50ppb.

The reaction of bisulfite with oxygen is typically faster at higher temperatures and can be facilitated by transition metal ion catalysts, e.g. Cobalt.

The most common applications of oxygen scavenger in oil and gas production are for seawater injection facilities, hydro-testing, and acid stimulation

It is used to arrest oxygen in sea water

It removes Entrapped Oxygen and thus reduces Corrosion

In Oil Drilling Chemicals

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



CorroSOL 66 Corrosion Scale Inhibitor Boiler

Size:

Color:

Product Short Description: Corrosion and Scale Inhibitor with Phosphates and Polyphosphates.
Product Technical Specification:
Appearance Paly Yellow, Clear liquid
Density 1.01-1.1
Boiling Poitnt  100 degree celcius
pH Alkaline

 

Not Compatible : Aluminium, Copper, Copper Alloys, Nickel, Neoprene, Polyurethane.
Remarks:

Frequently Asked Questions about Boiler treatment

Q1. What is a corrosion scale inhibitor and why is it important for boilers?

Answer:

A corrosion scale inhibitor is a chemical solution designed to prevent rust, corrosion, and scale formation inside boiler systems. It protects metal surfaces from degradation and ensures smooth heat transfer, ultimately extending the lifespan of the boiler and reducing energy costs and maintenance downtime.

Q2 How do I choose the right scale inhibitor for my boiler?

Answer:

Choosing the right inhibitor depends on:

  • Boiler pressure and temperature

  • Feedwater quality (e.g., hardness, pH, oxygen content)

  • Type of scaling or corrosion (e.g., calcium carbonate vs. oxygen pitting)

Look for inhibitors that are multi-functional, offering both scale and corrosion protection, and ensure they’re compatible with your boiler material (carbon steel, copper alloys, etc.).

Q3 How often should I dose my boiler with a corrosion scale inhibitor?

Answer:

The frequency of dosing depends on your boiler’s operating conditions, feedwater quality, and the type of inhibitor used. Typically, dosing is done continuously through a dosing pump or daily during boiler operation. Regular water testing and monitoring (pH, conductivity, hardness) is essential to maintain the correct inhibitor levels and ensure optimal protection against corrosion and scale.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



CorroSOL 30 Polymer Caustic Scale Sludge Conditioner

Size:

Color:

Product Short Description: Product to be used in situations where the boiler water is contaminated with oil. This high performance product is applicable to both medium and low-pressure steam boilers in order to prevent sludge deposits.
Product Technical Specification:

This is a white high molecular weight solution. It is hydrophilic and of low causticity.
Appearance / Color : White, viscous liquid 

pH : 8
Odor : Odorless 
Remarks:

Our others valauable Products : 
BOILER TREAT ONE SHOT

Combined Boiler Water Conditioner

A one-product treatment for all auxiliary boilers including waste heat, and exhaust gas boilers. it prevents scale formation, inhibits corrosion and conditions sludge.

HARDNESS CONTROL
Boiler Water Conditioner

Added to the boiler water to maintain optimum phosphate level, which prevents calcium and magnesium hardness salts formation. The precipitate can be removed by blow-down.

ALKALINITY CONTROL
Boiler Water Conditioner 

Added to the boiler water to maintain optimum alkalinity level to prevent corrosion. Due to this, Ca and Mg hardness salts cannot form and the precipitate is removed by blow-down.

HYDRAZIDE
Oxygen Scavenger 
Used for rapid removal of oxygen in boiler feed water and condensate systems, which prevents corrosion. It is the alternative for hazardous and potentially carcinogenic products.

BOILER TREAT COMBI
Organic Boiler Water Treatment 
Special blended low molecular weight compounds that elevate boiler water pH to levels, which reduce corrosion. It also prevents under deposit corrosion caused by excess alkalinity.

LIQUID COAGULANT
Oil and Sludge Conditioner 

Used to prevent formation of adherent deposits and sticky sludge in boilers,which are then removed by normal blow-down. It can also be used in the event of an oil contamination.

CONDENSATE CONTROL
Steam and Condensate Conditioner 

Injected into the condensate pump to prevent corrosion in steam and condensate lines.It’s also used to protect idle boilers from corrosion. It neutralizes acidic conditions in condensate systems and volatilizes with steam.

COOL WATER TREAT NCLT
Corrosion and Scale Inhibitor 
Provides an effective anodic inhibitor treatment and protects ferrous and non-ferrous metals. It deposits a microscopic protective film on surfaces and has built-in pH buffering compounds. It controls formation of hard scale deposits.

EVEPORATOR TREAT
Prevention of scale in Evaporators
Used in both high and low pressure evaporators to prevent foaming, carry-over and scale formation. It’s safe to use where distillate is used for drinking purposes. It prevents scale formation and avoids the need for acid descaling.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



CorroSOL 26 Neutralised Sulphite

Size:

Color:

Product Short Description: Extremely suitable oxygen scavenger for low and medium pressure boilers.
Product Technical Specification:

 

Solubility (10 % Aquous Soln)  V. S. Hazy to clear solution.
pH Value of 5% Solution 3.5 to 4.5
Specific Gravity @ 25° C  1.310 – 1.370
Density, lbs/gal @ 25° C 10.9 - 11.3
Description Oxygen Scavenger for Boiler
Standard Packing 30 Kg / 50 Kg. / 250 kg HM HDPE Barrel
Remarks:

The most common oxygen scavengers in oilfield production are sodium bisulfite (SBS) and ammonium bisulfite (ABS). Ammonium bisulfite is more water soluble than sodium bisulfite and typically react with oxygen faster. However, ammonium in the ammonium bisulfite can promote bacteria growth.

Being a salt of a weak acid and a strong base, sodium bisulfite forms a significantly basic aqueous solution whereas ammonium bisulfite is only slightly basic at around pH 8. As a rule of thumb, 60ppm of 65wt% ammonium bisulfite is required to reduce the oxygen concentration in water from 9ppm to 50ppb.

The reaction of bisulfite with oxygen is typically faster at higher temperatures and can be facilitated by transition metal ion catalysts, e.g. Cobalt.

The most common applications of oxygen scavenger in oil and gas production are for seawater injection facilities, hydro-testing, and acid stimulation

It is used to arrest oxygen in sea water

It removes Entrapped Oxygen and thus reduces Corrosion

In Oil Drilling Chemicals

Images: Alt